Halon 1211, Halon 1301 and HFC 227
Defender Unit specifications

Description
The M1 and the C700M1 includes a Pump Deck Assembly and a Recovery Tank Assembly mounted on a portable carriage for easy mobility. The C1 is the UL listed Pump Deck Assembly only without the portable carriage and the C700 is the Pump Deck Assembly with and industrial cart option.

The Pump Deck Assembly can be easily removed from the carriage for tabletop operations. The control panel is part of the pump deck assembly with all valves, gauges, regulators and instructions conveniently located for easy operation. The pump filer and the quick connect couplings used during operations complete the assembly.

The Recovery Tank Assembly includes a vapor outlet valve and quick connector, a liquid outlet valve and quick connection, a pressure relief valve, pressurizing quick connectors with valve and gauge, liquid level gauge and drain plug. The Recovery tank is securely fastened to the portable carriage with four stainless steel bolts.

The Hose Kit Assembly is an accessory module included with each unit. It contains adaptors and hoses for completing the recovery, recycling and recharging functions for portable extinguishers, wheeled units and crash trucks. The customer must provide international adaptors. A leak detector and technical manual are included with the Hose Kit Assembly.

Operating Modes
Recovery Mode: The M1 and C1 system will recover Halon 1211 and nitrogen gas from existing charged fire equipment. The C700M1 and the C700 will recover Halon 1211, Halon 1301, and HFC 227. The unit requires evacuation and purging before switching from gas to gas. The clean dry Halon is then ready for storage or recharging after it has been tested.

Recharge Mode: The system will fill and pressurize empty fire equipment with clean, dry Halon 1211, 1301 and HFC227. Pressurizing over 250 psig requires nitrogen source.

Recirculation Mode: The system will process contaminated Halon 1211, Halon 1301, and HFC 227 from a storage tank, filter out contaminates and remove moisture.


Component Assembly Performance Characteristics

Pump Deck Assembly M1/C1 C700M1/C700
Pump Flow Rate: 16.5lbs/min at 70o F (7.5kgs/min at 21o C) 16.5lbs/min at 70o F (7.5kgs/min at 21o C)
Maximum Pressure: 240 PSIG regulated by unit
Minimum Vacuum: 20 in. Hg. 20 in. Hg.
Pump Driver: Air Drive Cylinder/4” stroke/5:1 ratio Air Drive Cylinder/4” stroke/5:1 ratio
Pump Air Supply Required: Air Flow 16 CFM at 150 PSIG (10 Bar) Air Flow 16 CFM at 150 PSIG (10 Bar)
Air Operating Pressure: 65-85 PSIG (4.5-5.9 Bar) 65-85 PSIG (4.5-5.9 Bar)
Pump Relief Valve Pressure Set 260 PSIG internal (18 Bar) 360 PSIG internal (25 Bar)
Recovery Tank Assembly M1 C700M1
Tank Capacity: 500lbs (225 kgs) Halon 1211 500lbs (225 kgs) Halon 1211
350lbs (160 kgs) Halon 1301
325lbs (150 kgs) HFC 227
Design Pressure: 240 PSIG (16.5 Bar) 400 PSIG (27.5 Bar)
Relief Valve Set: 230 PSIG (16 Bar) 375 PSIG (27 Bar)

Hose Kit Assembly pressure rating – 2250 PSIG (155 Bar) for all units
Recommended Air Compressor (optional) – Model 0700 for stationary & 1 unit or Model 1500 for portable and multiple units.

Back to equipment page


Interested in hearing how RemTec International can help you? Enter your email address below:



COMPANY NEWS
  Recent News

 

Copyright 2006 Remtec International.
Home | About Remtec International | Our Services | Our Products | Buy & Sell | Contact Us

Toll-free refrigerant information, call 1-888-873-6832 -- Toll-free halon information, call 1-800-372-1301
1100 Haskins Road Bowling Green, Ohio 43402